Submersible Engineering Drainage Sewage Sludge Pump
Zoomed Image
Submersible Sewage Pump
Submersible Sewage Sludge Pump
Submersible Wastewater pumps
Submersible Dirty Water Pump
Submersible Sewage Water Pump
Submersible Slurry and Dirty Water Pumps
Water Drainage Pump

Submersible Engineering Drainage Sewage Sludge Pump

300TWQ132

Hydroman

$16,999.00 $18,999.00
Introduction:
Hydroman® Submersible Engineering Drainage Sewage Sludge Pump is a heavy-duty, corrosion-resistant pump designed to handle drainage water, raw sewage, and thick sludge in demanding engineering and municipal applications.
Pump Type:
Submersible Sewage Pump
Submersible Drainage Pump
Submersible Sludge Pump
Quantity :
-
1
+

Submersible Sewage Pump
Submersible Sewage Sludge Pump
Submersible Wastewater pumps
Submersible Dirty Water Pump
Submersible Sewage Water Pump
Submersible Slurry and Dirty Water Pumps
Water Drainage Pump

Description

Hydroman® Submersible Engineering Drainage Sewage Sludge Pump is engineered for demanding dewatering and sludge-handling operations in civil engineering, infrastructure, mining, and tunneling environments. Designed for submersion in high-solid-content and abrasive fluids, hydroman® submersible wastewater pump offers robust performance, non-clogging operation, and long-lasting durability in harsh site conditions.

 

Hydroman® Submersible Engineering Drainage Sewage Sludge Pump Technical Specifications

Model

Capacity

(m3/h)

Head

(m)

Speed

(r/min)

Power

(kw)

Efficiency

(%)

Weight

(kg)

300TW0600-6-18.5500-7505-7147018.561-69650
300TWO600-7-22500-7506-814702261-69660
300TWO700-11-30550-10008-139803072-77780
300TWO700-14-37550-100010-169803772-77880
300TWQ700-16-45550-100012-189804572-771150
300TWQ700-19-55550-100014-219805570-751215
300TWQ1000-20-75800-140015-239907575-821530
300TWQ1000-24-90800-140018-279909075-821650
300TWQ1000-28-110800-140020-31148011075-821720
300TWQ1000-35-132800-140027-38148013275-821800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hydroman® Submersible Engineering Drainage Sewage Sludge Pump Conditions of Use

• The medium temperature should not be over 60℃, the density 1200Kg/m3, and the PH value within 5-9.

• During running, the pump must not be lower than the lowest liquid level, see"lowest liquid level" in the drawing of installation dimensions (covering the automatic cooling system),means lowest liquid level without no automatic cooling system.
• Rated voltage 380V, rated frequency 50Hz. The motor can run successfully only under the condition the deviations of both rated voltage and frequency are not over ±5%.

• The maximum diameter of the solid grain going through the pump has not to be larger than 50% of that of the pump outlet.

 

Hydroman® Submersible Engineering Drainage Sewage Sludge Pump Check of Use

• Carefully check if thee is any deformation or damage with the pump and any looseness or fall-off with the fasteners during transport, storage and installation.
• Check if any damage or fracture with the cable,if the seal on its inlet intact and make a proper treatment in time if any possible leakage or bad seal is found.
• Measure the dielectricresistance between the phases and between the phase and ground with a 500V megohm 2 meter, the value of which has not to be lower than megohm,otherwise a drying treatment must be taken for the statorwinding of the motor with a temperature not over 120℃ or notify the manufacturer for help.
• Check if there is oil in the oil chamber and do not stop filling it until it overflows on the filler.
• Check if the serew cork and sealing pad on the oil chamber are full and if the serew cork presses the sealing pad tightly.

• Check if the impeller rotates flexibly.

• Check if the power device safe, reliable or normal and if the grounding wire inside of the cable reliably grounded.

• Before placing the pump in the pool, check if it is in a correct. Direction of rotation by way of dot moving and cut off the power andchange the U,V, W three wires with any two of which in the electric control cabinet if not correct.

 

Hydroman® Submersible Engineering Drainage Sewage Sludge Pump Regular Checking

• Periodically check the dielectric resistance between phases and between phase and ground, the value of which should not be lower than 2 megohm, otherwise it has to be removed to overhaul, and, at the same time, check if the grounding is secured and reliable.
• Replace the seal ring with a new one when the max.interval of it, mounted on the impeller neck and pump casing,is over 2mm.
• After half a year running ofthe pump under the provided working medium condition,check the state of the oil chamber and replace it with Nl0 mechanical oil if it shows emulsifed state. It is possible that the mechanical seal on the pump. Side is made damaged when the leakage probe gives a warning with the pump running for a short time after the oil replacement and replace it at once. More often check the pump when it is used under a very adverse working condition.
• After one year work of the pump under the normal working condi tion, a big overhaul must be taken for replacing the wornout parts, checking the fasteners and supplementing or replacing the grease on the bearing so as to ensure a good lubrication of the pump during its running.
• To disassemble, do not knock at it at will in order to avoid damaging the seal and do not allow non-skilled persons to do that in order not cause it leaking or the motor damaged.


Contact Hydroman® for Model Selection, Installation Recommendations, and Project-specific Technical Documentation

Contact: Jasmine Huang
Mob/WhatsApp: +8618132668739
Email: Sales10@tobeepump.com

 

Reviews

(0 reviews)
5 star

0%
4 star

0%
3 star

0%
2 star

0%
1 star

0%
Average rating: 5
based on 0 reviews

Share your thoughts with other customers

Write a Review
Most Recent
Most Recent
Earliest
Highest Rating
Lowest Rating
Pictures First
Most Recent
Most Recent
Earliest
Highest Rating
Lowest Rating
Pictures First
Request a Quote
Share your project details, and we’ll deliver a precise and competitive quote promptly.

Name*

Email*

Tel.*

Country*

Company Name*

Your Web*

Your message*

0/1000

Upload your file*

Upload File

    CAPTCHA*

    Submitted successfully

    Your submission has been received. Thanks for your time

    Continue shopping

    You May Also Like

    Chatting closeChat

    sendFile
    Donna
    取消
    取消